<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-24 03-57-25
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 68 kHz 13399 11,0531
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,28 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 68 kHz MIN: 12 kHz % above 76 kHz: 11,0531 Acquired: 2025/05/24 3.56.21 Total samples: 13399 Equivalent time: 0:11:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,9 dBr MIN: 4,6 dBr AVE: 5,28 dBr % above 12,2 dBr: 0,0 Last value: 5,7 dBr (2025/05/24 3.56.21) 03.42 03.44 03.46 03.48 03.50 03.52 03.54 03.56 0 2 4 6 Pm [dBr]